C610H Auto Tensile Tester is professionally applicable to measurement of  tensile, peeling, deformation, tearing, heat sealing, adhesive, puncture force,  opening force, pulling force and low speed unwrapping force as well as other properties  of plastic films, composite materials, soft package materials, plastic flexible  tube, adhesives, adhesive tapes, label stickers, medical plasters, release  paper, protective films, combined caps, aluminum foils, diaphragms, back  sheets, non-woven fabrics, rubber and paper, etc. 
 Product FeaturesNote1 
 Professional Test Modes to Meet  Various Testing Demands 
  -  Multiple  independent test modes including tensile test, peel test, tearing test, heat  seal test, tensile test at fixed elongation, and compression test, etc. at users’  choice 
   -  The  instrument supports bidirectional testing modes and test speed can be adjusted  freely 
   -  Intelligent  designs of over-travel protection, overload protect and automatic position  reset guarantee safe test operation of the users 
 
 Excellent  Testing Mechanism & Improved Test Accuracy 
  -  Force  measuring system is supplied by top global supplier, which ensures the testing  accuracy of better than 0.5% of full scale and guarantees accurate test results  and good repeatability. Multiple test ranges can be selected freely. 
   -  Servo  control system powered by top global supplier and the patented high-precision  ball screw multi-point positioning technology provide displacement accuracy of  better than 0.5% of full scale and infinitely variable speed, facilitate the  instrument with simplified and stable operation. 
   -  Global  renowned brand pneumatic control system supports pneumatic specimen clamping,  which avoids the specimen slipping and guarantees the accuracy of test data 
 
 High-end, Secure and  Easy-to-Use Embedded Computer-controlled System 
  -  Large  size touch screen tablet for better viewing and easy operation 
   -  Brand  new software and system provide smooth and simplified operating experience 
   -  The  system supports displaying and comparison analysis of group of test data as  well as unit conversions of test results. 
   -  Labthink’s  unique data security design by separating the test data from the computer,  totally avoids the system software malfunctions caused by computer virus or  faulty operations, conforms to the requirements for data traceability of China  GMP (optional). 
   -  The  instrument is equipped with USB ports and Internet ports for convenient data  transmission. 
   -  Unique DataShieldTM system supports centralized management of test data and can be connected to  other information management system. 
 
 Test StandardNote1 
 ISO 37, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330,  ASTM F88, ASTM F904, JIS P8113, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T  1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T 4850-2002, GB/T 12914-2008,  GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, GB/T  17590, QB/T 2358, QB/T 1130 
Applications
 C610H is equipped with more than 100 grips for  tests of more than 1000 materials. Customization is available for special  material tests. Examples of instrument applications: 
            | Basic Applications |     
          |  Shearing Test  |     
          |  Test of Tensile Strength and Elongation Rate  |     
          |  Test of Tensile Strength at Break  |     
          |  Tear Resistance Test  |     
          |  Heatseal Strength Test  |     
          |  90 Degree Peel Test  |     
          |  180 Degree Peel Test  |     
          |  Tensile Strength Test at Defined Elongation  |     
          Extended Applications   (Additional Accessories Required) |     
          |  Puncture Test of Hypodermic Needles in Artificial Skin  |        Puncture Test of Films  |     
          |  Puncture Test of Infusion Bags  |        Puncture/Pullout Test of Flexible Rubber Closures  |     
          |  Opening Resistance Test of Combined Covers  |        Tear Test of ZD - Type Caps  |     
          |  Opening Force Test of Oral Liquid Caps  |        Puncture/Pullout Test of Oral Liquid Caps  |     
          |  90 Degree Pullout Test of Infusion Bag Caps  |        Pullout Test of Infusion Bag Caps  |     
          |  23 Degree Pullout Test of Bottle Caps  |        Puncture/Pullout Test of Bottle Caps or Rubber Closures  |     
          |  90 Degree Peel Test of Adhesive Tapes  |        Tear Resistance Test of Adhesive Binding Books  |     
          |  90 Degree Peel Test of Water-soluble Plasters  |        Tear Resistance Test of Adhesives  |     
          |  Adhesive Strength Test (soft)  |        Adhesive Strength Test (hard)  |     
          |  Peel Test of Flexible Tube Caps  |        Removal Force of Pipes and Pipe Joints  |     
          |  Pullout Test of Cosmetic Brush Hair  |        Pullout Test of Tooth Brush Hair  |     
          |  Tensile Strength of Ropes at Break  |        Opening Force Test of Jelly Cups and Yogurt Cups  |     
          |  Peel Test of Cup Films  |        Pullout Test of Rubber Stoppers  |     
          |  45 Degree Peel Test of Bottle Membranes  |        Tensile Strength of Sealing Bags  |     
          |  Peel Test of Magnetic Cores  |        90 Degree Peel Test of Magnetic Cards  |     
          |  Tear Resistance of Heat Sealing Films  |        Separating Force of Protection Films  |     
          |  Peel Test of Release Paper  |        Tear Test Using Trouser Method  |     
          |  Unwrapping Force of Adhesive Tapes  |        Compressive Resistance of Plastic Bottles  |     
          |  20 Degree Peel Test  |        135 Degree Peel Test of Plugs  |     
          |  Peeling Grips of Floating Rollers  |        Eccentric Grips  |     
          |  Wide Sample Grips  |        Japanese Sample Grips  |     
          |  British Sample Grips  |        Tensile Strength of Contact Lenses at Break  |     
          |  Compression Resistance of Jelly Cups  |        Compression Resistance of Package  |     
          |  Compression Resistance of Sponge  |         |     
  
 Technical SpecificationsNote2 
            | Specifications |       C610H Auto Tensile Tester |     
          | Load Cell Capacity |       500 N (standard)          50 N, 100 N, 250 N, 1000 N (optional) |     
          | Accuracy |       ±0.5% of indicated value (2%FS~100%FS)         ±0.01%FS (0% ~ 2%FS) |     
          | Resolution |       0.001 N |     
          | Test Speed |       0.05 ~ 500 mm/min |     
          | Speed Accuracy |       ±0.5% of indicated value (1%~100% of maximum speed) |     
          | Number of Specimens |       1 |     
          | Specimen Width |       30 mm (Standard Grip) |     
          | 50 mm (Optional Grip) |     
          | Clamping Way |       Pneumatic Specimen Clamp |     
          | Gas Supply |       Air (outside of supply scope) |     
          | Gas Supply Pressure |       0.5 MPa~ 0.7 Mpa (72.5psi~101.5psi) |     
          | Stroke |       1000 mm |     
          | Instrument Dimension |       500 mm (L) × 520 mm (W) × 1900 mm (H) |     
          | Power Supply |       220VAC±10% 50Hz / 120VAC±10% 60Hz |     
          | Net Weight |       110 kg |     
  
Configurations
  -  Standard Configurations 
   -  Instrument, Professional Software, Tablet, Pneumatic Sample Grips 
 
  -  Optional Parts 
   -  Standard Pressure Roller, Test Plate, Sample Cutter, Customized Grips, Laser Printer, Air Compressor, Computer System required by GMP, DataShieldTM Note3 
 
  -  Note 
   -  1. The gas supply port of this instrument is Φ4mm PU Tubing;
    2. Customers need to prepare gas supply.  
 Note 1: The described test standard, applications and product  features should be in line with Technical Specifications.
  Note 2: The parameters in the table are measured by  professional operators in Labthink laboratory under strictly controlled  laboratory conditions. 
  Note 3: DataShieldTM provides safe and reliable  data application support. Multiple Labthink instruments can share one single  DataShieldTM system which can be configured as required. 
 Contact Us!       We can help you select or customize the proper unit for your test requirements.